1,057 research outputs found

    Підготовка адвокатом позовної заяви до суду

    Get PDF
    Аналізуються питання, пов’язані із підготовкою адвокатом позовної заяви до суду.Анализируется вопросы связаны с подготовкой адвокатом искового заявления в суд.The question connected with preparation of the point of claim to the court by the lawyer is analysed

    Compressive Sensing of Signals Generated in Plastic Scintillators in a Novel J-PET Instrument

    Full text link
    The J-PET scanner, which allows for single bed imaging of the whole human body, is currently under development at the Jagiellonian University. The dis- cussed detector offers improvement of the Time of Flight (TOF) resolution due to the use of fast plastic scintillators and dedicated electronics allowing for sam- pling in the voltage domain of signals with durations of few nanoseconds. In this paper we show that recovery of the whole signal, based on only a few samples, is possible. In order to do that, we incorporate the training signals into the Tikhonov regularization framework and we perform the Principal Component Analysis decomposition, which is well known for its compaction properties. The method yields a simple closed form analytical solution that does not require iter- ative processing. Moreover, from the Bayes theory the properties of regularized solution, especially its covariance matrix, may be easily derived. This is the key to introduce and prove the formula for calculations of the signal recovery error. In this paper we show that an average recovery error is approximately inversely proportional to the number of acquired samples

    Application of the Compress Sensing Theory for Improvement of the TOF Resolution in a Novel J-PET Instrument

    Get PDF
    Nowadays, in Positron Emission Tomography (PET) systems, a Time of Flight information is used to improve the image reconstruction process. In Time of Flight PET (TOF-PET), fast detectors are able to measure the difference in the arrival time of the two gamma rays, with the precision enabling to shorten significantly a range along the line-of-response (LOR) where the annihilation occurred. In the new concept, called J-PET scanner, gamma rays are detected in plastic scintillators. In a single strip of J-PET system, time values are obtained by probing signals in the amplitude domain. Owing to Compress Sensing theory, information about the shape and amplitude of the signals is recovered. In this paper we demonstrate that based on the acquired signals parameters, a better signal normalization may be provided in order to improve the TOF resolution. The procedure was tested using large sample of data registered by a dedicated detection setup enabling sampling of signals with 50 ps intervals. Experimental setup provided irradiation of a chosen position in the plastic scintillator strip with annihilation gamma quanta

    Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography

    Full text link
    Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic scintillators which would allow for single bed imaging of the whole human body. This paper describes a novel method of hit-position reconstruction based on sampled signals and an example of an application of the method for a single module with a 30 cm long plastic strip, read out on both ends by Hamamatsu R4998 photomultipliers. The sampling scheme to generate a vector with samples of a PET event waveform with respect to four user-defined amplitudes is introduced. The experimental setup provides irradiation of a chosen position in the plastic scintillator strip with an annihilation gamma quanta of energy 511~keV. The statistical test for a multivariate normal (MVN) distribution of measured vectors at a given position is developed, and it is shown that signals sampled at four thresholds in a voltage domain are approximately normally distributed variables. With the presented method of a vector analysis made out of waveform samples acquired with four thresholds, we obtain a spatial resolution of about 1 cm and a timing resolution of about 80 p

    The ATLAS SCT grounding and shielding concept and implementation

    Get PDF
    This paper presents a complete description of Virgo, the French-Italian gravitational wave detector. The detector, built at Cascina, near Pisa (Italy), is a very large Michelson interferometer, with 3 km-long arms. In this paper, following a presentation of the physics requirements, leading to the specifications for the construction of the detector, a detailed description of all its different elements is given. These include civil engineering infrastructures, a huge ultra-high vacuum (UHV) chamber (about 6000 cubic metres), all of the optical components, including high quality mirrors and their seismic isolating suspensions, all of the electronics required to control the interferometer and for signal detection. The expected performances of these different elements are given, leading to an overall sensitivity curve as a function of the incoming gravitational wave frequency. This description represents the detector as built and used in the first data-taking runs. Improvements in different parts have been and continue to be performed, leading to better sensitivities. These will be detailed in a forthcoming paper

    METHODOLOGY, CHARACTERISATION AND RESULTS FROM THE PROTOTYPE BEAM LOSS MONITORING ASIC AT CERN

    Get PDF
    The characterisation of novel beam loss monitoring front-end converters, based on radiation-hardened application-specific integrated circuits (ASIC), is undergoing at CERN. An effective performance analysis of the newly developed ASICs plays a key role in their candidacy for the future installation in the HL-LHC complex. This work introduces the latest test-bed architecture, used to characterise such a device, together with the variety of audits involved. Special focus is given on the verification methodology of data acquisition and measurements, in order to allow a detailed study of the conversion capabilities, the evaluation of the device resolution and the linearity response. Finally, the first results of post-irradiation measurements are also reported

    Progress in development of the readout chip for the ATLAS semiconductor tracker

    Get PDF
    The development of the ABCD chip for the binary readout of silicon strip detectors in the ATLAS Semiconductor Tracker has entered a pre-production prototyping phase. Following evaluation of the ABCD2T prototype chip, necessary correction in the design have been implemented and the ABCD3T version has been manufactured in the DMILL process. Design issues addressed in the ABCD3T chip and performance of this pre-production prototype are discussed

    Initial rhythm control with cryoballoon ablation vs drug therapy: Impact on quality of life and symptoms

    Get PDF
    Background Cryoballoon ablation (CBA) as a first-line rhythm control strategy is superior to antiarrhythmic drugs (AADs) for preventing atrial fibrillation (AF) recurrence; the impact of first-line CBA on quality of life (QoL) and symptoms has not been well characterized. Methods Patients aged 18 to 75 with symptomatic paroxysmal AF naïve to rhythm control therapy were randomized (1:1) to CBA (Arctic Front Advance, Medtronic) or AAD (Class I or III). Symptoms and QoL were assessed at baseline, 1, 3, 6, 9, and 12 months using the EHRA classification and Atrial Fibrillation Effect on QualiTy-of-Life (AFEQT) and SF-36v2 questionnaires. Symptomatic palpitations were evaluated via patient diary. Results Overall, 107 patients were randomized to CBA and 111 to AAD; crossovers occurred in 9%. Larger improvements in the AFEQT summary, subscale and treatment satisfaction scores were observed at 12 months with CBA vs AAD (all P <0.05). At 12 months, the mean adjusted difference in the AFEQT summary score was 9.9 points higher in the CBA group (95% CI: 5.5 –14.2, P <0.001). Clinically important improvements in the SF-36 physical and mental component scores were observed at 12 months in both groups, with no significant between group differences at this timepoint. In the CBA vs AAD group, larger improvements in EHRA class were observed at 6, 9 and 12 months (P <0.05) and the incidence rate of symptomatic palpitations was lower (4.6 vs 15.2 days/year post-blanking; IRR: 0.30, P <0.001). Conclusions In patients with symptomatic AF, first-line CBA was superior to AAD for improving AF-specific QoL and symptoms.publishedVersio

    A double-sided, shield-less stave prototype for the ATLAS upgrade strip tracker for the high luminosity LHC

    Get PDF
    A detailed description of the integration structures for the barrel region of the silicon strips tracker of the ATLAS Phase-II upgrade for the upgrade of the Large Hadron Collider, the so-called High Luminosity LHC (HL-LHC), is presented. This paper focuses on one of the latest demonstrator prototypes recently assembled, with numerous unique features. It consists of a shortened, shield-less, and double sided stave, with two candidate power distributions implemented. Thermal and electrical performances of the prototype are presented, as well as a description of the assembly procedures and tools

    A double-sided silicon micro-strip super-module for the ATLAS inner detector upgrade in the high-luminosity LHC

    Get PDF
    The ATLAS experiment is a general purpose detector aiming to fully exploit the discovery potential of the Large Hadron Collider (LHC) at CERN. It is foreseen that after several years of successful data-taking, the LHC physics programme will be extended in the so-called High-Luminosity LHC, where the instantaneous luminosity will be increased up to 5 × 1034 cm−2 s−1. For ATLAS, an upgrade scenario will imply the complete replacement of its internal tracker, as the existing detector will not provide the required performance due to the cumulated radiation damage and the increase in the detector occupancy. The current baseline layout for the new ATLAS tracker is an all-silicon-based detector, with pixel sensors in the inner layers and silicon micro-strip detectors at intermediate and outer radii. The super-module is an integration concept proposed for the strip region of the future ATLAS tracker, where double-sided stereo silicon micro-strip modules are assembled into a low-mass local support structure. An electrical super-module prototype for eight double-sided strip modules has been constructed. The aim is to exercise the multi-module readout chain and to investigate the noise performance of such a system. In this paper, the main components of the current super-module prototype are described and its electrical performance is presented in detail
    corecore